4.9 (226) · € 1679.99 · Auf Lager
If you are looking critical care medical equipment, then just visit Outfront Medical. We are your one-stop place to buy, sell and rent refurbished medical equipment at great prices.contact us at 609-388-4635 to know prices.
The Babylog 8000 plus is designed for harmonious ventilation of small children and the smallest pre-term babies. It has an advanced upgrade platform that has allowed it to keep pace with all new forms of treatment and clinical advances.
Sensitive synchronisation with gentle but precise support for spontaneous breathing reduces the work of breathing and makes the ventilation process much more comfortable for patients.
Product Description
The Babylog 8000 plus is designed for harmonious ventilation of small children and the smallest pre-term babies. It has an advanced upgrade platform that has allowed it to keep pace with all new forms of treatment and clinical advances.
Sensitive synchronisation with gentle but precise support for spontaneous breathing reduces the work of breathing and makes the ventilation process much more comfortable for patients.
TECHNICAL SPECIFICATIONS:
Controls
Conventional ventilation: continuous flow, pressure-limited, time-cycled
Triggered ventilation: SIMV, SIPPV, PSV1), leak adapted- Trigger: Flow/volume trigger, leak adapted- Trigger delay: approx. 40-60 ms
High Frequency Ventilation: CPAP+HFV, IMV+HFV- Frequency: 5 to 20 Hz
Volume Guarantee Ventilation: SIMV+VG, SIPPV+VG, PSV+VG
Oxygen mixer loss (bleed flow): 0 (zero) L/min
Settings
Inspiratory oxygen concentration: 21-100 vol.% oxygen
Peak inspiratory pressure: 10 to 80 mbar
PEEP/CPAP: 0 to 25 mbar
Maximal frequency: 200 bpm
Inspiratory time: 0.1 to 2 seconds
Expiratory time: 0.2 to 30 seconds
Inspiratory flow: 1 to 30 L/min
Base Flow (VIVE): 1 to 30 L/min
Monitoring
Flow monitoring: at the Y-piece, integrated
Volume monitoring: at the Y-piece, integrated
Lung function monitoring: compliance, resistance C20/C
Method: linear regression analysis
FiO2 monitoring: integrated
Real-time curves: Flow and pressure, integrated
Inspiratory oxygen concentration: 21-100 vol.% oxygen
Peak pressure: to 99 mbar
Mean airway pressure: to 99 mbar
Graphic trends: 6 parameters, integrated
Logbook: record of up to 100 alarms
Refurbished - Drager Babylog 8000 Plus Ventilator - Avante Health
Babylog® 8000 plus
Dräger Babylog 8000 8410280-38, Ventilator, Product Details, SW 5.01 LFT, Hours of operation: 4304, MFG 2010, Condition, As-Is for Parts. Displays
Dräger Babylog 8000 8410280-38 Ventilator | SW 5.01 LFT | As-Is for Parts
Manual Usuario (Enghlis) Babylog 8000 Plus, PDF
More than 40 years of experience in neonatal ventilation and a century of expertise in breathing technology have gone into Dräger Medical’s Babylog®
Drager Babylog 8000 Plus Neonatal Ventilator
Used DRAEGER BABYLOG 8000 Plus Ventilator For Sale - DOTmed
Dräger Babylog® VN600
Drager Babylog 8000 Ventilatorr - For Sale — Integris Equipment LLC
Drager Babylog 8000 Plus Infant ICU Ventilator in England, United
Babylog 8000 series Technical Documentation IPM Rev 1.0 PDF download
Refurbished - Drager Babylog 8000 Plus Ventilator - Avante Health